当前位置:首页 > 报告详情

DC25_PAPER_Track08_STARTSelfAdaptingToolFor_Unakafov.pdf

上传人: S** 编号:1240762 2026-05-16 25页 2.49MB

1、 Information Classification:General START:Self-Adapting Tool for Automated Receiver Testing-using receiver-specific stress symbol sequences for above-compliance testing Anton Unakafov,BitifEye, Valentina Unakafova,BitifEye, David Bouse,BitifEye, Fabian Deuchler,BitifEye, Parthasarathy Raju,BitifEye,

2、 Alexander Schmitt,BitifEye, Manav Madan,Furtwangen University,manav.madanhs-furtwangen.de Christoph Reich,Furtwangen University,christoph.reichhs-furtwangen.de Information Classification:General Abstract As link speeds increase,testing receivers with all symbol sequences of relevant length in reaso

3、nable time becomes challenging.For example,testing receivers at 32 Gbd with all 40-symbol sequences takes 1 minute for NRZ,but a million years for PAM4.For this reason,compliance testing becomes insufficient one can neither measure long-term pre-FEC BER,nor identify the causes of receiver errors.We

4、introduced the Self-adapting Tool for Automated Receiver Testing(START)to make robust Rx testing possible in a reasonable time.START performs detailed error analysis,identifies the likely error cause,generates the worst-case test pattern,and assesses long-term pre-FEC BER.Building on last years mode

5、ling results,this paper presents START results across several physical setups and demonstrates STARTs accuracy in identifying the causes of errors.We also examine the theoretical foundation of START.Author(s)Biography Anton Unakafov is a scientist at BitifEye,where he leads test&measurement research

6、 projects.He has been working in industry since 2003,developing mathematical methods and algorithms for signal processing,time series analysis,and modelling of nonlinear systems.He received his Ph.D.in 2015 from the University of Lbeck,www.BitifE Valentina Unakafova is a scientist at BitifEye.Since

word格式文档无特别注明外均可编辑修改,预览文件经过压缩,下载原文更清晰!
三个皮匠报告文库所有资源均是客户上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作商用。
1. **START技术**:针对高速接收器(Rx)测试,通过自适应算法识别最易出错的符号序列(PSS),解决传统合规测试无法覆盖长序列(如PCIe 7.0需4^90符号,测试时间超宇宙年龄)的问题。 2. **核心数据**: - PCIe 6.0 PAM4测试需4^45≈10^27符号,耗时百万年;START通过迭代修改测试模式(如120次修改使SER提升7倍)。 - 实验显示,START能准确定位误差原因(如ISI或抖动),并估算真实SER(如模型中SER达2.9E-6)。 3. **应用价值**:生成合规的最坏情况测试模式(CPSS),优化均衡器(EQ),适用于100+ Gb/s接口,提升接收器鲁棒性测试效率。