1、Sponsored byData Technical Summit IBM TechXchange 2025Availability AND Performance:async system managed duplexing and Db2s LOCK1 structureSession 3147Async duplexing of Db2 for z/OS LOCK1 structureMark RaderIBM Z WSC Db2 for z/OS SpecialistDoes Parallel Sysplex and data sharing solve,or prevent,avai

2、lability problems?IBM TechXchange|2025 IBM Corporation2If we implement Parallel Sysplex and Db2 for z/OS data sharing(*)will we achieve 100%availability?Sysplex and data sharing provide the infrastructure upon which to build high availability solutions.One part of that infrastructure,the Db2 lock st

3、ructure,is the focus of this session.Agenda010203040506Parallel Sysplex conceptsStructure rebuild and duplexingSystem managed duplexing(SMD)Synch SMD vs.Async SMDUse cases for Async SMDCustomer experiencesIBM TechXchange|2025 IBM CorporationParallel Sysplex basics for Db2 for z/OS Multiple Db2 membe

4、rs comprise a Db2 data sharing group Coupling facility(CF)structures provide high-speed sharing of locks,status,and data(tables,indexes)Managed by cross-system extended services,or XES CFs run coupling facility control code(CFCC)ssnmIRLM allocates the lock structure:dsngrp_LOCK1 ssnmMSTR allocates t

5、he shared communication area:dsngrp_SCA ssnmDBM1 allocates a group buffer pool(GBP)for each local BP with shared data:dsngrp_GBPn GBPs not pictured;spread across both CF LPARsIBM TechXchange|2025 IBM Corporation4Parallel Sysplex basics for Db2 for z/OS LOCK1 and SCA are required structuresIf Db2 can

6、not allocate them,Db2 failsIf LOCK1 lost,all IRLMs required to rebuild LOCK1If SCA lost,all MSTRs required to rebuild SCARebuild to the alternate CF LPARIBM TechXchange|2025 IBM Corporation5Original Parallel Sysplex configuration;at least 4 systems 2 central electronic complexes(CECs)with production

word格式文档无特别注明外均可编辑修改,预览文件经过压缩,下载原文更清晰!
三个皮匠报告文库所有资源均是客户上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作商用。
根据报告的内容,全文主要内容概括如下: 1. **Parallel Sysplex 和 Db2 for z/OS 数据共享**:Parallel Sysplex 和 Db2 for z/OS 数据共享提供高可用性基础设施,Db2 锁结构是其关键部分。 2. **结构重建和双工**:讨论了结构重建和双工的概念,包括系统管理双工(SMD)和异步 SMD。 3. **异步 SMD 的优势**:异步 SMD 减少了系统管理双工的开销,提高了可用性和性能,尤其是在多站点操作中。 4. **成本效益分析**:异步 SMD 的成本低于同步 SMD,但需要额外的 CF 引擎和耦合链路。 5. **案例研究**:提供了不同配置下的案例研究,展示了异步 SMD 如何提高可用性和性能。 6. **推荐配置**:推荐使用系统管理双工来双工 LOCK1 和 SCA,以提高可用性和性能。 7. **结论**:异步 CF 双工对于锁结构提供了强大的故障恢复能力、高可用性、类似单工的响应时间、即使在远程位置也能保持性能,并具有灵活的配置。