Single phase immersion cooling developments – Research Institutes of Sweden OCP Experience Center working with Castrol.pdf

上传人: 张** 编号:161432 2024-05-05 15页 1.45MB

1、Single phase immersion cooling developments Research Institutes of Sweden OCP Experience Center working with CastrolDr Jon Summers,Scientific Lead in Data Centers,RISE ICE Datacenter,SwedenNick Barrett,Senior Engineer,Castrol,United KingdomSingle phase immersion cooling developments Research Institu

2、tes of Sweden OCP Experience Center working with CastrolPOWER AND COOLINGCOOLING ENVRISE has the ICE datacenter test and demo facility which is an OCP experience center.Good testbed telemetry brings facts to the data center server immersion community.Castrol have developed dielectric thermal fluids

3、for data center immersion cooling application and continue to research future formulations.Together RISE and Castrol are supporting data center server immersion developments with a technology focus.The goal has been to put the servers and their performance and operability at the center of the collab

4、oration.RISE and Castrol working in partnership.Castrol are developing immersion coolants.*GWP Global Warming Potential.Referring to GWP from leakage into the environment based on 2021 UK Government GHG Conversion Factors for Company Reporting Department for Business,Energy&Industrial Strategy and D

5、epartment for Environmental Food&Rural AffairsLow ViscosityEnabling efficient heat transfer and good pumpabilityProven Thermal PropertiesAcross the operating temperature rangeStrong Electrical CharacteristicsProtecting against breakdown and ignitionHigh Fluid StabilityMaintaining performance over th

6、e fluid lifetimeLow GWP*/Low ODPAll Castrol ON fluids are in line with Castrols PATH360 sustainability programmeRISE ICE datacenter testbed(fixed ambient)RISE ICE datacenter testbedRISE ICE datacenter data collectionPull data from devices.Many protocols.Open source Data provenance tracking.Open sour